BEGIN:VCALENDAR
VERSION:2.0
PRODID:icalendar-ruby
CALSCALE:GREGORIAN
BEGIN:VEVENT
DTSTAMP:20260808T204000Z
UID:213dd9a7-3d67-4e16-b8a8-104b9e7103e3
DTSTART:20171023T090000Z
DTEND:20171024T170000Z
DESCRIPTION:The course consists of interactive lectures\, discussions\, and
  imbedded exercises. Participants will also be placed in several real life
  situations where they complete a compliance review of a schematic process
  flow diagram\, analyze failures using trend reports\, critique a risk ass
 essment\, and perform a change control analysis including the impact of re
 quested or proposed modifications.\n\nThe course is designed to provide th
 e attendee with a practical understanding of the following topics:\n•Bas
 ic water chemistry\n•Water quality selection criteria\n•EPA\, EU\, and
  WHO drinking water standards\n•The governing regulatory agencies with d
 irect impact on water systems\n•Analytical water grades (1\, 2\, 3) and 
 reagent water types (I\, II\, III\, IV\, with A\, B &amp\; C subgroups)\n
 •Pharmacopeia water grades (Purified\, Highly Purified\, Water for Injec
 tion &amp\; Clean Steam)\n•Pretreatment component equipment - selection 
 and operating principals\n•Final treatment options (reverse osmosis\, va
 por compression\, single-effect and multiple-effect stills)\n•Opportunit
 ies for energy and water resource conservation\n•Point of use criteria s
 uch as temperature\, location\, time-of-day\, and demand (GPM &amp\; GPD)\
 n•System design including materials of construction\, generation\, stora
 ge and distribution options\n•Trend reports (analysis\, problem identifi
 cation\, predictive value)\n•Control systems\, data historian\, secure a
 ccess\, set points and alarms\n•Managing performance deviations and comp
 onent failure\n•Direct and in-direct impact analysis\n•Quality by desi
 gn including risk assessment\n•Instrument calibration for critical\, non
 -critical\, and informational only devices\n•Maintenance impacts to syst
 em performance\, reliability\, and validation\n•The importance of as-bui
 lt documentation - user and field directed changes\n
LOCATION:The Berlin Hilton
SUMMARY:Water Purification Systems for Regulated Industries
URL;VALUE=URI:https://www.cfpie.com/ProductDetails.aspx?ProductID=287
END:VEVENT